Licro Odyssey CLX Western blot imaging

Homepage Instrument preview
Licro Odyssey CLX Western blot imaging

Licro Odyssey CLX Western blot imaging

Instrument category: Biochemistry Core

Instrument mode:

Unit: 浙江大学 > ZJU-UoE Institute

Instrument manufacturer: Licor

Purchase date: 2019-10-31

Usage patterns: Machine-time reservation

Specification: Odyssey CLX

Room number:----

Collection

Reservation

Instrument manufacturer: Licor

Asset number: 20036964

Asset manager: ----

Purchase date: 2019-10-31

Instrument price: 0.00 Ten thousand yuan

Origin of instruments: USA

Instrument supplier: ----

Purchase manager: ----

Main accessories: ----

Main parameter: Image Field Size: 25 x 25 cm Scanning speed: 5-40cm/s Wavelength(s):685 and 785 nm Resolution:21 to 337 µm Environment: 13-35℃, dew point temperature <20℃ Focal length: adjustable within the range of 0mm-4mm

Introduction of instruments:

With Odyssey CLx Infrared Imaging System, you can get clearer answers with accurate reproducible Western blots and more. Infrared detection gives you the quantitative analysis and wide linear dynamic range that chemiluminescence and visible fluorescence cannot.


With the Odyssey CLx Imaging System, you can:

  • Get consistent reproducible digital images, without the hassles and unpredictability of film

  • See both strong and faint bands in the same image with excellent sensitivity and no image saturation

  • Multiplex with two fluorescent colors to see even more data, and increase your quantification accuracy by using the second color for normalization. You have options for normalization. Let’s work together to develop your experimental design and normalization strategy for the best Western blotting data

  • Capture all the detail and complexity of your data and get results that you can be confident in when submitting for publication or using for proposal submissions to funding agencies

  • Perform many different applications, including near-infrared fluorescent Western blots, cell-based assays (such as In-Cell Western™ or On-Cell Western assays), protein and nucleic acid gel imaging, tissue section imaging, fluorescent EMSAs, and more


Working hours: 00:00-23:59
Minimum reservation time interval: 0.083333333333333 Hours
Maximum reservation time interval: 168 Hours
Minimum unit time of calendar: 0.083333333333333 Hours
Latest reservation time: Unauthorized user: 0Hours; General qualified user: 0Hours; Senior qualified user: 0Hours
Earlist reservation time: Unauthorized: 8 Week 0 o'clock; Ordinary: 8 Week 0 o'clock; Senior: 8 Week 0 o'clock
Reservation protection time: 15 minutes
No-show protection time: 15 minutes
Outage delay time: 30 Seconds
Minimum power-on time: 5 Seconds
Timeout reminder: 1200 Seconds
Maximum effective number of reservations: 5 次/ Day
Costless revocation of reservation time: 30 minutes

Main instrument manager: 李媛(邮箱:yuanli@intl.zju.edu.cn)

Instrument manager: Chew TingGang(邮箱:tinggchew@intl.zju.edu.cn)

Instrument manager: 沈杭晨(邮箱:shc14124818@163.com)

Instrument manager: 贾玲燕(邮箱:lingyanjia@intl.zju.edu.cn)

Instrument manager: 刘娣(邮箱:diliu@intl.zju.edu.cn)

Instrument manager: 王依依(邮箱:21716013@zju.edu.cn)

Instrument manager: 金梦迪(邮箱:mengdijin@intl.zju.edu.cn)

Instrument manager: 周博诚(邮箱:bochengzhou@intl.zju.edu.cn)

Instrument manager: 朋德测试(邮箱:11111@qq.com)

Instrument manager: 蔡政(邮箱:675097016@qq.com)

Instrument manager: 朱乐(邮箱:11616028@zju.edu.cn)

User qualification Working hours Non working time
Unauthorized qualification Need to review Need to review
General qualification Avoid audit Avoid audit
Senior qualification Avoid audit Avoid audit
To be audited
Valid
Completed
Breach of contrac
Occupied
No. Title Creation time Operation
No. Title File number Creation time Operation
1 Licor Odyssey Clx NIR Bicolor Laser Imaging System Training Manual - 2020(English ) 2 2023-09-19 13:56:39 Download files
2 Licor Odyssey Clx NIR Bicolor Laser Imaging System Training Manual - 2020(Chinese ) 1 2023-09-19 13:55:58 Download files
Title Training Video Creation time Operation