Diagenode PICO Bioruptor

Homepage Instrument preview
Diagenode PICO Bioruptor

Diagenode PICO Bioruptor

Instrument category: Biochemistry Core

Instrument mode:

Unit: 浙江大学 > ZJU-UoE Institute

Instrument manufacturer: Diagenode

Purchase date: 2019-09-20

Usage patterns: Sample presentation reservation,Machine-time reservation

Specification: B01060010 (PICO)

Room number:公共技术平台 A108

Collection

Reservation

Instrument manufacturer: Diagenode

Asset number: 20036965

Asset manager: ----

Purchase date: 2019-09-20

Instrument price: 0.00 Ten thousand yuan

Origin of instruments: Belgium

Instrument supplier: ----

Purchase manager: Lin Jiangtao

Main accessories: Automatic temperature control; Motorized lid; Tube holders.

Main parameter: Power supply: 100-230V, 50/60Hz, 2.1A (EU) / 4.2A (US); Ultrasonic wave frequency: 20-60 kHz; Ultrasonic wave output power: 25-210 W; Sonication unit dimensions: 350 (W) x 245 (D) x 280 (H) mm; Sonication bath volume: 750 ml; Timer: Digital; Possibility to control water flow via connector kit for Bioruptor Cooler:Yes; Tube holder:Available for 0.1, 0.2, 0.65, 1.5 or 15 ml tubes; Total weight: 7,90 kg; Number of samples to be processed simultaneously; 0.1 ml tubes – 12 samples、 0.2 ml tubes – 16 samples、 0.65 ml tubes – 12 samples、 1.5 ml tubes – 6 samples、 15 ml tubes – 6 samples.

Introduction of instruments:

Diagenode’s Bioruptor Pico uses a gentle method of sonication to retain the integrity of DNA and/or biological complexes, including chromatin, protein-protein binding, protein-DNA complexes and other biochemical and biological assay systems. The Bioruptor Pico sonication system uses a sonication bath to generate indirect sonication waves, which emanate from an ultrasound element below the water tank. Because the system is gentler than other sonicators, the Bioruptor Pico produces better and more consistent results than with harsher sonication methods. Up to 16 closed tubes can be sonicated in parallel and the continuous rotation of tubes allows even distribution of the energy for efficient sonication. The Bioruptor Pico enables automation of sonication, guaranteeing higher reproducibility of results.


Working hours: 09:00-12:00;14:00-18:00
Minimum reservation time interval: 0.25 Hours
Maximum reservation time interval: 168 Hours
Minimum unit time of calendar: 0.25 Hours
Latest reservation time: Unauthorized user: 0Hours; General qualified user: 0Hours; Senior qualified user: 0Hours
Earlist reservation time: Unauthorized: 8 Week 0 o'clock; Ordinary: 8 Week 0 o'clock; Senior: 8 Week 0 o'clock
Reservation protection time: 15 minutes
No-show protection time: 15 minutes
Outage delay time: 30 Seconds
Minimum power-on time: 5 Seconds
Timeout reminder: 1200 Seconds
Maximum effective number of reservations: 5 次/ Day
Costless revocation of reservation time: 120 minutes

Main instrument manager: 王依依(邮箱:21716013@zju.edu.cn)

Instrument manager: Chew TingGang(邮箱:tinggchew@intl.zju.edu.cn)

Instrument manager: 沈杭晨(邮箱:shc14124818@163.com)

Instrument manager: 贾玲燕(邮箱:lingyanjia@intl.zju.edu.cn)

Instrument manager: 刘娣(邮箱:diliu@intl.zju.edu.cn)

Instrument manager: Rachel Tea(邮箱:821719339@qq.com)

Instrument manager: 金梦迪(邮箱:mengdijin@intl.zju.edu.cn)

Instrument manager: 周博诚(邮箱:bochengzhou@intl.zju.edu.cn)

Instrument manager: 朋德测试(邮箱:11111@qq.com)

Instrument manager: 蔡政(邮箱:675097016@qq.com)

Instrument manager: 李媛(邮箱:yuanli@intl.zju.edu.cn)

Instrument manager: 朱乐(邮箱:11616028@zju.edu.cn)

User qualification Working hours Non working time
Unauthorized qualification Need to review Need to review
General qualification Avoid audit Avoid audit
Senior qualification Avoid audit Avoid audit
To be audited
Valid
Completed
Breach of contrac
Occupied
No. Title Creation time Operation
No. Title File number Creation time Operation
Title Training Video Creation time Operation