Cytek Aurora Flow Cytometry

Homepage Instrument preview
Cytek Aurora Flow Cytometry

Cytek Aurora Flow Cytometry

Instrument category: Flowcytemetry Core

Instrument mode:

Unit: 浙江大学 > ZJU-UoE Institute

Instrument manufacturer: Cytek

Purchase date: 2020-09-01

Usage patterns: Machine-time reservation

Specification: Aurora

Room number:A124

Collection

Reservation

Instrument manufacturer: Cytek

Asset number: 20036909

Asset manager: ----

Purchase date: 2020-09-01

Instrument price: 222.16 Ten thousand yuan

Origin of instruments: America

Instrument supplier: BEIJING CY-TECH BIOTECH CO.LTD

Purchase manager: 林江涛

Main accessories: ----

Main parameter: Available lasers: 488nm、640nm、405nm、561nm; Detectors: forward and side scatter+fluorescent detectors(Violet detector module: 16 channels unevenly spaced bandwidth from 420-829 nm; Blue detector module: 1 4 channels unevenly spaced bandwidth from 498-829 nm; Red detector module: 8 channels unevenly spaced bandwidth from 652-829 nm; Yellow-Green detector module: 10 channels unevenly spaced bandwidth from 567-829 nm) Sensitivity: FITC≤110MEFL、PE≤35MEFL、APC≤20MEFL

Introduction of instruments:

The Aurora spectral flow cytometer is an air-cooled, multi-laser, compact benchtop flow cytometer. It is equipped with four lasers and up to 48 detection channels for fluorescence and up to two detection channels for scatter (FSC [forward scatter] and violet laser SSC [side scatter]). Solid-state lasers transmit light through a flow cell where particles in suspension are focused, single file for interrogation by the laser. Proprietary, high-sensitivity, 16-channel semiconductor detector arrays are equipped to capture the emission spectra of dyes that emit in the 400 to 900-nm wavelength range. The resulting fluorescence and scatter are then collected and converted into electronic signals. On-board electronics convert these signals into digital data that can be acquired and recorded on the workstation.


Working hours: 08:30-17:00
Minimum reservation time interval: 0.25 Hours
Maximum reservation time interval: 168 Hours
Minimum unit time of calendar: 0.25 Hours
Latest reservation time: Unauthorized user: 2Hours; General qualified user: 0Hours; Senior qualified user: 0Hours
Earlist reservation time: Unauthorized: 8 Week 0 o'clock; Ordinary: 8 Week 0 o'clock; Senior: 8 Week 0 o'clock
Reservation protection time: 15 minutes
No-show protection time: 15 minutes
Outage delay time: 30 Seconds
Minimum power-on time: 5 Seconds
Timeout reminder: 1200 Seconds
Maximum effective number of reservations: 5 次/ Day
Costless revocation of reservation time: 720 minutes

Main instrument manager: 沈杭晨(邮箱:shc14124818@163.com)

Instrument manager: 贾玲燕(邮箱:lingyanjia@intl.zju.edu.cn)

Instrument manager: 刘娣(邮箱:diliu@intl.zju.edu.cn)

Instrument manager: 王依依(邮箱:21716013@zju.edu.cn)

Instrument manager: 金梦迪(邮箱:mengdijin@intl.zju.edu.cn)

Instrument manager: 周博诚(邮箱:bochengzhou@intl.zju.edu.cn)

Instrument manager: 朋德测试(邮箱:11111@qq.com)

Instrument manager: 蔡政(邮箱:675097016@qq.com)

Instrument manager: 李媛(邮箱:yuanli@intl.zju.edu.cn)

Instrument manager: 朱乐(邮箱:11616028@zju.edu.cn)

User qualification Working hours Non working time
Unauthorized qualification No reservation No reservation
General qualification Avoid audit No reservation
Senior qualification Avoid audit Avoid audit
To be audited
Valid
Completed
Breach of contrac
Occupied
No. Title Creation time Operation
No. Title File number Creation time Operation
1 Aurora training 1 2021-10-20 10:56:27 Download files
2 AURORA_NL操作手册(基础版) 1 2021-10-20 10:55:01 Download files
3 Aurora User's Guide 2 2021-10-20 10:54:12 Download files
4 Fluorochrome Guide 1 2021-10-20 10:52:39 Download files
Title Training Video Creation time Operation
Training video of cytek 1694396819izkyk.mp4 2023-09-11 09:48:45 Detail