PHOTON IMAGERTM OPTIMA

Homepage Instrument preview
PHOTON IMAGERTM OPTIMA

PHOTON IMAGERTM OPTIMA

Instrument category: Biochemistry Core

Instrument mode:

Unit: 浙江大学 > ZJU-UoE Institute

Instrument manufacturer: Biospace

Purchase date: 2020-10-10

Usage patterns: Sample presentation reservation,Machine-time reservation

Specification: Optima

Room number:动物房

Collection

Reservation

Instrument manufacturer: Biospace

Asset number: 20033667

Asset manager: 贾玲燕

Purchase date: 2020-10-10

Instrument price: 160.00 Ten thousand yuan

Origin of instruments: American

Instrument supplier: 杭州宝诚生物技术有限公司

Purchase manager: 林江涛

Main accessories: ----

Main parameter: High sensitivity: 37ph/s/st/cm²; High spatial resolution: 2.5μm; High time resolution: 13ms; High throughput: 14; Full spectrum imaging (covering visible light to near-infrared light) for bioluminescence, fluorescence and Cherenkov imaging; Excitation band: 400nm-800nm; Receiving band: 370nm-900nm;

Introduction of instruments:

The Photon Imagers are dynamic, modular systems for the non-invasive detection, localization and quantification of dynamic optical signal - bioluminescence or fluorescence – from live animals. A unique photon counting technology makes it extremely sensitive from the very start of image acquisition and enables the unparalleled kinetic recording of dynamic processes without the need for setting acquisition time, or pixel binning prior to imaging. The PhotonIMAGER™ continuously displays the light distribution during an experiment and image acquisition can be stopped at any time. This is a key advantage for luminescence imaging and can open new horizons for fluorescence imaging. Unlike other pre-clinical Imaging systems, the real-time imaging capability of the PhotonIMAGER™ delivers impressive performance, whilst its modular design ensures that the systems capabilities can be extended, as further state-of-the-art imaging technologies become available.

Working hours: 09:00-12:00;14:00-18:00
Minimum reservation time interval: 0.25 Hours
Maximum reservation time interval: 168 Hours
Minimum unit time of calendar: 0.25 Hours
Latest reservation time: Unauthorized user: 0Hours; General qualified user: 0Hours; Senior qualified user: 0Hours
Earlist reservation time: Unauthorized: 8 Week 0 o'clock; Ordinary: 8 Week 0 o'clock; Senior: 8 Week 0 o'clock
Reservation protection time: 15 minutes
No-show protection time: 15 minutes
Outage delay time: 30 Seconds
Minimum power-on time: 5 Seconds
Timeout reminder: 1200 Seconds
Maximum effective number of reservations: 5 次/ Day
Costless revocation of reservation time: 120 minutes

Main instrument manager: 王依依(邮箱:21716013@zju.edu.cn)

Instrument manager: 沈杭晨(邮箱:shc14124818@163.com)

Instrument manager: 贾玲燕(邮箱:lingyanjia@intl.zju.edu.cn)

Instrument manager: 刘娣(邮箱:diliu@intl.zju.edu.cn)

Instrument manager: 金梦迪(邮箱:mengdijin@intl.zju.edu.cn)

Instrument manager: 周博诚(邮箱:bochengzhou@intl.zju.edu.cn)

Instrument manager: 朋德测试(邮箱:11111@qq.com)

Instrument manager: 蔡政(邮箱:675097016@qq.com)

Instrument manager: 沈梦露(邮箱:menglushen@intl.zju.edu.cn)

Instrument manager: 李媛(邮箱:yuanli@intl.zju.edu.cn)

Instrument manager: 朱乐(邮箱:11616028@zju.edu.cn)

User qualification Working hours Non working time
Unauthorized qualification Need to review Avoid audit
General qualification Avoid audit Avoid audit
Senior qualification Avoid audit Avoid audit
To be audited
Valid
Completed
Breach of contrac
Occupied
No. Title Creation time Operation
No. Title File number Creation time Operation
1 Notes 1 2023-10-08 10:33:35 Download files
2 Boot process and precautions 1 2023-10-08 10:32:20 Download files
3 USER GUIDE_BIOSPACE LAB_M3 Vision 1 2022-09-06 13:11:31 Download files
4 Manual in Chinese 1 2022-09-06 13:11:06 Download files
5 BSL PI Optima User guide 1 2022-05-27 09:46:05 Download files
Title Training Video Creation time Operation
Analysis software operation video 1696732194ffrpt.mp4 2023-10-08 10:30:05 Detail
operation video 1696732040dufsp.mp4 2023-10-08 10:26:51 Detail