Licor Odyssey FC Western Blot Imaging System

Homepage Instrument preview
Licor Odyssey FC Western Blot Imaging System

Licor Odyssey FC Western Blot Imaging System

Instrument category: Biochemistry Core

Instrument mode:

(QIN Jiyao)

Unit: 浙江大学 > ZJU-UoE Institute

Instrument manufacturer: Licor

Purchase date: 2019-12-14

Usage patterns: Machine-time reservation

Specification: Odyssey/FC

Room number:暂无

Collection

Reservation

Instrument manufacturer: Licor

Asset number: 20001755

Asset manager: ----

Purchase date: 2019-12-14

Instrument price: 0.00 Ten thousand yuan

Origin of instruments: USA

Instrument supplier: ----

Purchase manager: ----

Main accessories: ----

Main parameter: 像场尺寸:10 cm×12 cm Fc成像托盘(内部尺寸):14 cm x 12cm CCD像素尺寸:6.45微米 动态范围*:22位(> 6个对数) 最佳样品聚焦的景深:6 mm 获得专利的FieldBrite™XT2技术:整个场的CV <3% 激光寿命:20,000小时的运行时间 700通道激光光源:685 nm的固态二极管激光器 800通道激光光源:785 nm的固态二极管激光器 光源:600 nm漫射光源 探测器:低噪声CCD。 热电冷却。 采集时间:荧光(700和800 nm)通道:30 s,2分钟,10分钟以及可变时间功能。 化学发光通道:30 s,2分钟,10分钟,60分钟以及可变时间功能。 聚焦:自动

Introduction of instruments:

The Odyssey Fc System is the only imaging system that offers superior chemiluminescent detection and the benefits of quantitative infrared Western blot detection as well as the ability to document DNA gels using the 600nm channel. The Odyssey Fc System allows your lab to combine the proven advantages of infrared fluorescence detection with simple, streamlined qualitative chemiluminescence detection on one instrument.

  • Do More by Going Digital: Get consistent, reproducible digital images, without the hassles and unpredictability of film – so you can analyze your data right away and plan your next experiment. 

  • See More with Additional Channels and Clearer Images: Document DNA gels, image ECL blots, and detect multiple targets on the same blot with two channel near-infrared fluorescence. Capture clear, low-background images every time without adjusting camera settings. 

  • Discover More with Richer, More Complete Data: Capture all the detail and complexity of your data. With 6 logs of linear dynamic range, your results are more reproducible. Near-infrared fluorescence delivers consistent signals that aren’t affected by timing.


Working hours: 0:00-24:00
Minimum reservation time interval: 0.083333333333333 Hours
Maximum reservation time interval: 168 Hours
Minimum unit time of calendar: 0.083333333333333 Hours
Latest reservation time: Unauthorized user: 0Hours; General qualified user: 0Hours; Senior qualified user: 0Hours
Earlist reservation time: Unauthorized: 8 Week 0 o'clock; Ordinary: 8 Week 0 o'clock; Senior: 8 Week 0 o'clock
Reservation protection time: 15 minutes
No-show protection time: 15 minutes
Outage delay time: 30 Seconds
Minimum power-on time: 5 Seconds
Timeout reminder: 1200 Seconds
Maximum effective number of reservations: 5 次/ Day
Costless revocation of reservation time: 30 minutes

Main instrument manager: 李媛(邮箱:yuanli@intl.zju.edu.cn)

Instrument manager: Chew TingGang(邮箱:tinggchew@intl.zju.edu.cn)

Instrument manager: 沈杭晨(邮箱:shc14124818@163.com)

Instrument manager: 贾玲燕(邮箱:lingyanjia@intl.zju.edu.cn)

Instrument manager: 刘娣(邮箱:diliu@intl.zju.edu.cn)

Instrument manager: 王依依(邮箱:21716013@zju.edu.cn)

Instrument manager: 金梦迪(邮箱:mengdijin@intl.zju.edu.cn)

Instrument manager: 周博诚(邮箱:bochengzhou@intl.zju.edu.cn)

Instrument manager: 朋德测试(邮箱:11111@qq.com)

Instrument manager: 蔡政(邮箱:675097016@qq.com)

Instrument manager: 朱乐(邮箱:11616028@zju.edu.cn)

User qualification Working hours Non working time
Unauthorized qualification Need to review Need to review
General qualification Avoid audit Avoid audit
Senior qualification Avoid audit Avoid audit
To be audited
Valid
Completed
Breach of contrac
Occupied
No. Title Creation time Operation
No. Title File number Creation time Operation
1 Licor Odyssey FC NIR Two-color Laser Imaging System Training Manual - 2020 (English) 2 2023-09-19 13:59:01 Download files
2 Licor Odyssey FC NIR Two-color Laser Imaging System Training Manual - 2020 (Chinese) 1 2023-09-19 13:58:21 Download files
Title Training Video Creation time Operation