Tecan Spark Microplate Reader

Homepage Instrument preview
Tecan Spark Microplate Reader

Tecan Spark Microplate Reader

Instrument category: Biochemistry Core

Instrument mode:

Unit: 浙江大学 > ZJU-UoE Institute

Instrument manufacturer: Tecan

Purchase date: 2019-12-14

Usage patterns: Sample presentation reservation,Machine-time reservation

Specification: Spark

Room number:A108-core facility

Collection

Reservation

Instrument manufacturer: Tecan

Asset number: 21008937

Asset manager: ----

Purchase date: 2019-12-14

Instrument price: 58.19 Ten thousand yuan

Origin of instruments: Austria

Instrument supplier: ----

Purchase manager: ----

Main accessories: ----

Main parameter: Luminescence Specification Wavelength range: 370-700 nm Integration time/well: 10 - 60000 ms Attenuation: 1 OD, 2 OD, 3 OD Alpha Specifications Excitation time/well: 10 - 1000 ms Integration Time/well:10 - 60000 ms Detection Limit 384-well plate low volume (Omnibeads) < 12.5 ng/ml Uniformity 384-well plate low volume (Omnibeads) < 8 CV Absorbance Specifications Wavelength range 200 - 1000 nm, selectable in 1 nm steps Wavelength accuracy ≤ 0.8 nm Wavelength reproducibility ≤ 0.5 nm Bandwidth fixed wavelength 3.5 nm Measurement range 0 - 4 OD Measurement time 96-well, 1 flash < 14 seconds Measurement time 384-well, 1 flash < 30 seconds Fluorescence Specifications Wavelength range Excitation: 230 – 900 nm Emission: 280 – 900 nm Integration time 20 µs – 2000 µs Lag time 0 µs – 2 ms

Introduction of instruments:

The SPARK is a multifunctional microplate reader platform and is robotic compatible.The SPARK microplate multimode reader with a modular design is intended for use in research laboratories. Depending on the configuration, the instrument is intended for the measurement and data analysis of absorbance, fluorescence, time resolved fluorescence, fluorescence polarization and luminescence of biological and non-biological samples, as well as for the acquisition and analysis of bright field and fluorescence images. Additionally, the reader is suited for both endpoint and kinetic measurements with either single or multi-labels. The SPARK is equipped with SparkControl software for reader control and data reductio

Working hours: 09:00-17:00
Minimum reservation time interval: 0.083333333333333 Hours
Maximum reservation time interval: 168 Hours
Minimum unit time of calendar: 0.083333333333333 Hours
Latest reservation time: Unauthorized user: 0Hours; General qualified user: 0Hours; Senior qualified user: 0Hours
Earlist reservation time: Unauthorized: 8 Week 0 o'clock; Ordinary: 8 Week 0 o'clock; Senior: 8 Week 0 o'clock
Reservation protection time: 15 minutes
No-show protection time: 15 minutes
Outage delay time: 30 Seconds
Minimum power-on time: 5 Seconds
Timeout reminder: 1200 Seconds
Maximum effective number of reservations: 5 次/ Day
Costless revocation of reservation time: 120 minutes

Main instrument manager: 王依依(邮箱:21716013@zju.edu.cn)

Instrument manager: Chew TingGang(邮箱:tinggchew@intl.zju.edu.cn)

Instrument manager: 沈杭晨(邮箱:shc14124818@163.com)

Instrument manager: 贾玲燕(邮箱:lingyanjia@intl.zju.edu.cn)

Instrument manager: 刘娣(邮箱:diliu@intl.zju.edu.cn)

Instrument manager: 金梦迪(邮箱:mengdijin@intl.zju.edu.cn)

Instrument manager: 周博诚(邮箱:bochengzhou@intl.zju.edu.cn)

Instrument manager: 朋德测试(邮箱:11111@qq.com)

Instrument manager: 蔡政(邮箱:675097016@qq.com)

Instrument manager: 李媛(邮箱:yuanli@intl.zju.edu.cn)

Instrument manager: 朱乐(邮箱:11616028@zju.edu.cn)

User qualification Working hours Non working time
Unauthorized qualification Need to review Need to review
General qualification Avoid audit Avoid audit
Senior qualification Avoid audit Avoid audit
To be audited
Valid
Completed
Breach of contrac
Occupied
No. Title Creation time Operation
No. Title File number Creation time Operation
1 user guide 1 2021-01-11 22:25:52 Download files
2 spark instructions for use 1 2020-09-01 14:21:58 Download files
3 spark中文版说明书 1 2020-09-01 14:21:07 Download files
Title Training Video Creation time Operation